| Quantity: (2) | |
| HURST Hybrid Design, Coolidge, Georgia | |
| Maximum continuous rating of 80,000 lbs. | |
| 40,000 lbs. each at 450 psig design pressure | |
| Fuel: hog or rubber/hog mix | |
| Delivered steam condition: 400 psig at 700OF at 2800 feet elevation | |
| Convection heating surface per boiler: 5600 sq. ft. per unit | |
| Convection superheater: 1000 sq. ft. per unit | |
| Convection air heaters: 2220 sq. ft. per unit | |
| Convection water tube section: 1880 sq. ft. per unit | |
| Convection multicones: 800 sq. ft. per unit | |
| Convection hybrid section: 2050 sq. ft. per unit | |
| Steam Drum | |
| 80" x 20' w/5" fire tube section, 2' " water tube section | |
| Air Heater | |
| HURST Package | |
| Fans & Drives | |
| Induced draft (2) - 200 hp, 1800 rpm, plus one spare | |
| Fans, BUFFALO forged (2) 980 H16 | |
| Forced draft (2) - 75 hp, 1800 rpm, plus one spare | |
| Fans, BUFFALO forged (2) 540 BL | |
| Reinjection - MILLER 5 hp dual reinjection | |
| Water Column & Gauges | |
| YARWAY water column with multiple scale gauges, high/low alarms and dual shutoffs | |
| Superheaters | |
| Impregnated into three pass flue gas system of fire tube section. Built entirely of T-1 steel and lined w/stainless. | |
| Soot Blower | |
| (2) reinjection automatic blowers | |
| (1) ash chain feed to quenching tank | |
| Grates | |
| 8% manganese steel in four different configurations. Approximately (400) spare grates available | |
| Stokers | |
| Three per boiler. Each boiler has (3) separate fuel cells consisting of fuel box and screw stoker for under fire fuel feed. All are computer controlled for speed based on boiler load. | |
| (3) Fuel Conveying Systems | |
| (1) HURST 40'x 25' walking floor to incline conveyor | |
| (2) Belt from fuel silo to incline conveyor | |
| (3) Chain conveyor to 40 hp low pressure fan w/cyclone receiver and airlock above fuel carburetor. This system was installed to bypass incline conveyor (backup). | |
| Boiler-Combustion-Generator Controls | |
| HONEYWELL computerized closed-loop system over BAILEY & CHESSEL controllers and electronics. Can be set for boilers fallow turbine or turbine fallow boilers dependent on operations at that time. All functions in the plant are controlled by one system and one operator. | |
| De-aerater Feed Water Heater | |
| Size 80,000 pph | |
| Temperature 240OF | |
| Pressure psig 15 to 17 | |
| Design psig 35 | |
| Storage 25 minutes | |
| Multicone Dust Collectors | |
| HURST package | |
| Electrical System | |
| All transformers, etc., No PCB's | |
| 2400 KVA transformer | |
| 2400 to 12500 KVA transformer |  |
| 12500 DVA to 115000 transformer |  |
| All except 2400 transformer are in switchyard enclosure | |
| Motor control center - WESTINGHOUSE Series 2100 |  |
| Standby Diesel Generator | |
| 16V GMC diesel w/DELCO generator |  |
| 1125 KVA - 950 KW - 1355 Amp | |
| 500 gallon fuel tank | |
| Containerized enclosure | |
| Wet Scrubber | |
| ZURN scrubber w/(2) venturi inlets and 60" stack | |
| Settling tank w/circulation pumps | |
| Feed Water Pump | |
| (2) 125 hp, 1800 electric driven | |
| (2) 12 stage, 1400 psig pumps | |
| Each pump will supply both boilers | |
| Water Softeners | |
| BRUNER water softener with Mix-Roy | |
| 4-station chemical tanks and pumps | |
| Turbines | |
| WORTHINGTON full condensing turbine, s/n: 108115 | |
| 5000 KW 450 psig at 750OF | 
 |
| 6250 KVA 1960's model | |
| 1500/867 Amp 3600 rpm | |
| 3 ph 60 cycle 2400/4150 Volt | |
| w/WOODWARD governor, ALLIS-CHALMERS condenser | |
| G.E. Pressure Reducing Turbine, s/n: 640668 | |
| 400-450 psig to 150 psig | |
| 937.5 KVA Adjustable | |
| 3600 rpm | |
| 750 KW | |
| Both turbines w/SEDCO exciters | |
| 2500 gallon condensate Hotwell w/dual pumps | |
| Cooling Towers | |
| (4) - 1500 gallon TOWER SERVICES cooling towers w/(4) 75 hp, 1200 rpm circulation motors, (4) 25 hp fans. |  |
| 10,000 gallon fiberglass raw water holding tank w/enclosed pumping station | |
| SEDCO controls for generators, switchgear | |
| All plant pumps, motors, fans, etc. have spares and all spares are included in purchase price. Also numerous turbine parts, extra feed screws, etc. are included. | |
| There are also many extras included in this plant, too numerous to list. All will be available for inspection. | |
| ADDITIONS TO PLANT - 2001 | |
| 80,000 lb. FOSTER WHEELER gas/oil fired boiler. | 


 |
| TODD/JOHN ZINK low NOx dual fuel burner with gas and oil nozzles. | |
| PONDER Burner computer controls for burner system. | |
| Remote boiler computer controls by TPCI (TurnKey Process Controls) w/plasma touch screen and all associated equipment. | |
| All pumps, motors, fans, etc. were disassembled, re-bearinged and balanced. The turbine (5 MW) was disassembled and the turbine rotor and generator armature were checked out and balanced. | |
| The air ejector, coolers, trip throttle valve, governor, etc. were checked out, repaired and refurbished. The rotors were then laser aligned and the unit was reassembled. | |
| The transformers and cooling towers were completely inspected and refurbished. | |
| The plant was run at capacity in November and December, 2001, and January, 2002. | |
| PLANT MAINTAINED FOR STARTUP ON A WEEKLY BASIS | |
| SALE TERMS | |
Sale Price: $1.5-2 million
|